//

GAMBARAN PERLEKATAN GLASS IONOMER CEMENT MODIFIKASI SILIKA 5% DARI PASIR LAUT DENGAN GIGI MENGGUNAKAN SCANNING ELECTRON MICROSCOPE (SEM)

BACA FULL TEXT ABSTRAK Permintaan Versi cetak
Pengarang DWI SEPTIANI - Personal Name
SubjectRESTORATIVE SURGERY
Bahasa Indonesia
Fakultas Fakultas Kedokteran Gigi Universitas Syiah Kuala
Tahun Terbit 2019

Abstrak/Catatan

ABSTRAK Nama : Dwi Septiani Program Studi : Pendidikan Dokter Gigi Fakultas : Kedokteran Gigi Judul : Gambaran Perlekatan Glass Ionomer Cement Modifikasi Silika 5% dari Pasir Laut dengan Gigi Menggunakan Scanning Electron Microscope (SEM) Glass ionomer cement (GIC) merupakan bahan restorasi yang paling biokompatibel. Material GIC merupakan bahan restorasi yang dapat melekat pada email dan dentin secara fisiko kimiawi. Sifat adhesi gigi terhadap restorasi berpengaruh pada adaptasi marginal. Hal ini menyebabkan perbedaan nilai perlekatan. Perbedaan perlekatan tersebut dibutuhkan alternatif dengan menambahkan bahan bioactive glass silica pada powder GIC. Penelitian ini bertujuan untuk mendapatkan informasi tentang gambaran perlekatan glass ionomer cement modifikasi silika 5% dari pasir laut dengan gigi menggunakan scanning electron microscope. Pada penelitian ini, silika disintesis dari pasir laut menggunakan metode kopresitipasi. Spesimen penelitian berjumlah 4 gigi premolar rahang atas dengan kavitas klas I kemudian direstorasi, lalu dibagi menjadi dua kelompok. Kelompok A diaplikasikan GIC (Fuji IX) (n=2) dan kelompok B diaplikasikan dengan GIC modifikasi silika 5% dari pasir laut (n=2). Seluruh spesimen direndam dalam larutan pewarna biru 5% selama 24 jam kemudian dilakukan pengamatan dengan menggunakan scanning electron microscope (SEM) dan diukur rerata jarak antara bahan restorasi dengan gigi (email dan dentin). Hasil analisa deskriptif menunjukkan bahwa terdapat jarak antara bahan restorasi dengan permukaan gigi di bawah gambaran SEM, dengan rerata jarak antara GIC (Fuji IX) dan permukaan email dan dentin yaitu sebesar 11.74 ± 4.642 µm dan 13.52 ± 7.891 µm sementara jarak antara GIC modifikasi silika 5% dengan email dan dentin yaitu sebesar 6.31 ± 1.086 µm dan 9.33 ± 2.361 µm. Kesimpulan penelitian ini adalah terdapat perbedaan nilai rerata jarak antara bahan restorasi GIC modifikasi silika 5% dengan gigi lebih kecil dibandingkan GIC (Fuji IX). Kata Kunci: Glass Ionomer Cement (GIC), silika, perlekatan, Scanning Electron Microscope (SEM).  ABSTRACT Name : Dwi Septiani Study Program : Dentist Education Faculty : Dentistry Tittle : Description Attachment of Silica 5% Modified Glass Ionomer Cement from Sea Sand with Teeth by Using Scanning Electron Microscope (SEM) Glass ionomer cement (GIC) is the most commonly used restoration material because of biocompatible material. GIC is restoration material that can be attached to email and dentin physical chemically. The adhesion properties of teeth to restoration have an effect on marginal adaptation. This causes different attachment values. An alternative difference in attachment is needed by adding bioactive glass silica material to glass ionomer cement. In this study, silica was synthesized from sea sand by using kopresipitation method. This study aimed to obtain information about attachment of silica 5% modified glass ionomer cement from sea sand as mean value of distance between email and dentin surface with restoration by using Scanning Electron Microscope (SEM). Samples were 4 maxillary premolars were classified into two groups which were applied GIC (Fuji IX) (n=2) and silica 5% modified GIC as restorations (n=2). The specimens were immersed in 5% methylene blue solution for 24 hours, then were observed under SEM. The study specimens were observed the mean distance of the attachment of the restoration material with the teeth (email and dentin). Analysis descriptive statistics result showed mean value of distance between GIC (Fuji IX) with email and dentin surface were 11.74 ± 4.642 µm and 13.52 ± 7.891 µm while on silica 5% modified GIC with email and dentin were 6.31 ± 1.086 µm and 9.33 ± 2.361 µm. Conclusion of this study, there were a difference mean value of distance between silica 5% modified GIC with email and dentin had smaller distance, as compared to GIC (Fuji IX). Keywords : Glass Ionomer Cement (GIC), Restoration Material, Silica, Attachment.

Tempat Terbit Banda Aceh
Literature Searching Service

Hard copy atau foto copy dapat diberikan dengan syarat ketentuan berlaku, jika berminat, silahkan isi formulir online (Chat Service LSS)

Share Social Media

Tulisan yang Relevan

ANALISIS HASIL MODIFIKASI GLASS IONOMER CEMENT DENGAN PENAMBAHAN HIDROKSIAPATIT DAN SILIKA DARI BAHAN ALAM (DITINJAU DARI GUGUS FUNGSI MENGGUNAKAN FOURIER TRANSFORM INFRARED) (MOHD TAUFIQ KAMIL H, 2018)

KEKERASAN PERMUKAAN GLASS IONOMER CEMENT (GIC) SETELAH PENAMBAHAN 5% SILIKA DARI PASIR LAUT (Apriliadi Saputra, 2018)

GAMBARAN KETEBALAN BIOFILM PADA GLASS IONOMER CEMENT (GIC) TIPE II MODIFIKASI PENAMBAHAN SILIKA DARI SINTESIS PASIR PANTAI (REZA UMAMI, 2019)

GAMBARAN KETEBALAN BIOFILM PADA KOMBINASI GIC TIPE II DENGAN HAP DARI CANGKANG KERANG DARAH (ANADARA GRANOSA) DAN SIO2 DARI PASIR LAUT MENGGUNAKAN SCANNING ELECTRON MICROSCOPY (SEM) (AULIYA ATTAMIMI, 2019)

GAMBARAN KETEBALAN BIOFILM PADA GLASS IONOMER CEMENT MODIFIKASI HIDROKSIAPATIT 5% DARI SINTESIS CANGKANG KERANG DARAH (ANADARA GRANOSA) (Rani Milda Yanti, 2019)

  Kembali ke sebelumnya

Pencarian

Advance



Jenis Akses


Tahun Terbit

   

Program Studi

   

© UPT. Perpustakaan Universitas Syiah Kuala 2015     |     Privacy Policy